Multi-zone Amplifiers with Remote control calling via Microphone
Add to cart
RC-600
- Call Mic 6 zone
- External audio source via microphone on the same cable
- Chime Tone
- Priority
- Remote control for recorded message
Multi-zone Amplifiers with Remote control calling via Microphone
Add to cart
RC-610
- Call Mic 6 zone
- External audio source via microphone on the same cable
- Chime Tone
- Priority
Multi-zone Amplifiers with Remote control calling via Microphone
Add to cart
RM-2000
- Call Mic 20 Zone
- External audio source via a microphone on the same cable
- Chime Tone
- Priority
Multi-zone Amplifiers with Remote control calling via Microphone
Add to cart
RR-600
- Control card to operate the Zone microphone
- Installed inside the amplifier
- Controls 3 Mic
Multi-zone Amplifiers with Remote control calling via Microphone
Add to cart
S-5020D
- Amplifier 500 watts
- Division of 20 districts
- Class-D Series features high purity, beautiful audio clarity, noise canceling, and external noise for the speaker
- Contains 4 mic incomes
- It contains 2 stereo inputs
- It contains a stereo output for recording
- Control Bass & Trible on each income separately
- 4 calling tones and 2 emergency tones
- The ability to use the call and the call
- It is not possible to control the sound intensity for each region separately, but it is for all regions
- Integrated protection circuits
- It has a place to install the audio source units or the message unit
- It is installed directly in the Rack
- The remote control unit can be connected using the UTP cable RM-2000, with the ability to connect up to 32 units
Multi-zone Amplifiers with Remote control calling via Microphone
Add to cart
ZA-6240
- Amplifier 240 watts with 6 zones
- Can control the sound for each Zone separately
- Contains 3 mics for input
- Contains 2 RCA Stereo inputs
- Contains stereo output for recording
- Can be connected to other amplifiers
- Can be controlled (Equalizer) for each input separately
- The ability to connect a unit of sound messages to the fire alarm
- It contains 4 recall tones
- The possibility of using it with the central to call on the speaker
- Provided with a priority button
- It is equipped with an internal vehicle
- It is equipped with a multi-speed cooling fan that automatically
- Provided with protection circuits against high load
- Tone for the Chime microphone
- Protection against Short and Overheat
- A Chime or a siren tone can be made when calling or emergency
- It has a place to install the audio source units or the message unit
- It is installed directly in the Rack
Multi-zone Amplifiers with Remote control calling via Microphone
Add to cart
ZA-6360
- Amplifier 360 watts with 6 zones
- Can control the sound for each Zone separately
- Contains 3 mics for input
- Contains 2 RCA Stereo inputs
- Contains stereo output for recording
- Can be connected to other amplifiers
- Can be controlled (Equalizer) for each input separately
- The ability to connect a unit of sound messages to the fire alarm
- It contains 4 recall tones
- The possibility of using it with the central to call on the speaker
- Provided with a priority button
- It is equipped with an internal vehicle
- It is equipped with a multi-speed cooling fan that automatically
- Provided with protection circuits against high load
- Tone for the Chime microphone
- Protection against Short and Overheat
- A Chime or a siren tone can be made when calling or emergency
- It has a place to install the audio source units or the message unit
- It is installed directly in the Rack
Multi-zone Amplifiers with Remote control calling via Microphone
Add to cart
ZA-6480
- Amplifier 480 watts with 6 zones
- Can control the sound for each Zone separately
- Contains 3 mics for input
- Contains 2 RCA Stereo inputs
- Contains stereo output for recording
- Can be connected to other amplifiers
- Can be controlled (Equalizer) for each input separately
- The ability to connect a unit of sound messages to the fire alarm
- It contains 4 recall tones
- The possibility of using it with the central to call on the speaker
- Provided with a priority button
- It is equipped with an internal vehicle
- It is equipped with a multi-speed cooling fan that automatically
- Provided with protection circuits against high load
- Tone for the Chime microphone
- Protection against Short and Overheat
- A Chime or a siren tone can be made when calling or emergency
- It has a place to install the audio source units or the message unit
- It is installed directly in the rack
Multi-zone Amplifiers with Remote control calling via Microphone
Add to cart
ZA-6600
- Amplifier 600 watts with 6 zones
- Can control the sound for each Zone separately
- Contains 3 Mic For input
- Contains 2 RCA stereo inputs
- Contains stereo output for recording
- Can be connected to other amplifiers
- Can be controlled (Equalizer) for each input separately
- The ability to connect a unit of sound messages to the fire alarm
- It contains 4 recall tones
- The possibility of using it with the central to call on the speaker
- Provided with a priority button
- It is equipped with an internal vehicle
- It is equipped with a multi-speed cooling fan that automatically
- Provided with protection circuits against high loads
- Tone for the Chime microphone
- Protection against Short and Overheat
- A Chime or a siren tone can be made when calling or in an emergency
- It has a place to install the audio source units or the message unit
- It is installed directly in the Rack








